Differences
This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision | ||
manual:pws2-30k:safety_instructions [2019/01/03 01:38] admin [urposes of usage] |
manual:pws2-30k:safety_instructions [2020/09/16 22:16] (current) |
||
---|---|---|---|
Line 1: | Line 1: | ||
+ | ====== Safety instructions ====== | ||
+ | |||
+ | |||
energy storage inverter is designed and tested in strict accordance with relevant international safety standards. | energy storage inverter is designed and tested in strict accordance with relevant international safety standards. | ||
Line 30: | Line 33: | ||
* | * | ||
* Any system (equipment) damage caused by modification and disassembly without permission does not fall into the warranty scope. | * Any system (equipment) damage caused by modification and disassembly without permission does not fall into the warranty scope. | ||
- | </ | + | </ |
- | | + | |
- | ====== Safety instructions for mechanical installation | + | ===== Safety instructions for mechanical installation ===== |
<WRAP center round Danger 60%> | <WRAP center round Danger 60%> | ||
Line 40: | Line 42: | ||
<WRAP center round warning 60%> | <WRAP center round warning 60%> | ||
| | ||
- | </ | + | |
During equipment operation, the ventilation should be good. The equipment should be upright, and there should be no strong air current to prevent airflow so as to ensure that the device is cooled well. | During equipment operation, the ventilation should be good. The equipment should be upright, and there should be no strong air current to prevent airflow so as to ensure that the device is cooled well. | ||
+ | </ | ||
+ | |||
- | ====== Safety instructions for electrical connection | + | ===== Safety instructions for electrical connection ===== |
<WRAP center round Danger 60%> | <WRAP center round Danger 60%> | ||
Line 55: | Line 59: | ||
<WRAP center round warning 60%> | <WRAP center round warning 60%> | ||
| | ||
- | </ | ||
Grid-tied operation can be conducted after permission is obtained from local national/ | Grid-tied operation can be conducted after permission is obtained from local national/ | ||
Before power-on, please ensure that it is reliably grounded and the grounding meets local electrical standards. | Before power-on, please ensure that it is reliably grounded and the grounding meets local electrical standards. | ||
- | ====== Safety instructions for inverter operation | + | </ |
+ | |||
+ | ===== Safety instructions for inverter operation ===== | ||
<WRAP center round Danger 60%> | <WRAP center round Danger 60%> | ||
Line 79: | Line 84: | ||
</ | </ | ||
- | ====== Safety instructions for maintenance and replacement | + | ===== Safety instructions for maintenance and replacement ===== |
<WRAP center round danger 60%> | <WRAP center round danger 60%> | ||
| | ||
Line 104: | Line 109: | ||
<WRAP center round warning 60%> | <WRAP center round warning 60%> | ||
- | | + | |
- | </ | + | |
Don’t touch the circuit boards. | Don’t touch the circuit boards. | ||
+ | |||
Abide by electrostatic protection specifications and wear anti-static wrist strap. | Abide by electrostatic protection specifications and wear anti-static wrist strap. | ||
+ | </ | ||
+ | |||
- | ====== Others | + | ===== Others ===== |
<WRAP center round warning 60%> | <WRAP center round warning 60%> | ||
Line 118: | Line 125: | ||
</ | </ | ||
| | ||
- | ====== Precautions | + | ===== Precautions ===== |
- | ===== Personnel requirements | + | ==== Personnel requirements ==== |
Energy storage inverter must be debugged and maintained by the engineers designated by the manufacturer or its agent. Otherwise, it might endanger personal safety and result in device fault. Any damage against the device caused thereby will not fall into the warranty scope. | Energy storage inverter must be debugged and maintained by the engineers designated by the manufacturer or its agent. Otherwise, it might endanger personal safety and result in device fault. Any damage against the device caused thereby will not fall into the warranty scope. | ||
- | ===== Purposes of usage ===== | + | ==== Purposes of usage ==== |
Energy storage inverter is only used for commercial/ | Energy storage inverter is only used for commercial/ | ||
- | ===== Label on enclosure | + | ==== Label on enclosure ==== |
The label on enclosure contains important information for safe operation to the inverter. Don NOT tear down or damage it. | The label on enclosure contains important information for safe operation to the inverter. Don NOT tear down or damage it. | ||
The label on enclosure should be clear and readable. If it is damaged or becomes vague, please replace it. | The label on enclosure should be clear and readable. If it is damaged or becomes vague, please replace it. | ||
- | ===== Notes ===== | + | ==== Notes ==== |
To help users read this manual more conveniently, | To help users read this manual more conveniently, | ||