+ | ====== Safety instructions ====== | ||
+ | |||
+ | |||
energy storage inverter is designed and tested in strict accordance with relevant international safety standards. | energy storage inverter is designed and tested in strict accordance with relevant international safety standards. | ||
Line 8: | Line 11: | ||
The detailed description will be provided in relevant chapter. | The detailed description will be provided in relevant chapter. | ||
- | |||
- | |||
- | |||
Line 33: | Line 33: | ||
* | * | ||
* Any system (equipment) damage caused by modification and disassembly without permission does not fall into the warranty scope. | * Any system (equipment) damage caused by modification and disassembly without permission does not fall into the warranty scope. | ||
- | </ | + | </ |
- | | + | |
- | ====== Safety instructions for mechanical installation | + | ===== Safety instructions for mechanical installation ===== |
<WRAP center round Danger 60%> | <WRAP center round Danger 60%> | ||
Line 43: | Line 42: | ||
<WRAP center round warning 60%> | <WRAP center round warning 60%> | ||
| | ||
- | </ | + | |
During equipment operation, the ventilation should be good. The equipment should be upright, and there should be no strong air current to prevent airflow so as to ensure that the device is cooled well. | During equipment operation, the ventilation should be good. The equipment should be upright, and there should be no strong air current to prevent airflow so as to ensure that the device is cooled well. | ||
+ | </ | ||
+ | |||
- | ====== Safety instructions for electrical connection | + | ===== Safety instructions for electrical connection ===== |
<WRAP center round Danger 60%> | <WRAP center round Danger 60%> | ||
Line 58: | Line 59: | ||
<WRAP center round warning 60%> | <WRAP center round warning 60%> | ||
| | ||
- | </ | ||
Grid-tied operation can be conducted after permission is obtained from local national/ | Grid-tied operation can be conducted after permission is obtained from local national/ | ||
Before power-on, please ensure that it is reliably grounded and the grounding meets local electrical standards. | Before power-on, please ensure that it is reliably grounded and the grounding meets local electrical standards. | ||
- | ====== Safety instructions for inverter operation | + | </ |
+ | |||
+ | ===== Safety instructions for inverter operation ===== | ||
<WRAP center round Danger 60%> | <WRAP center round Danger 60%> | ||
Line 82: | Line 84: | ||
</ | </ | ||
- | ====== Safety instructions for maintenance and replacement | + | ===== Safety instructions for maintenance and replacement ===== |
<WRAP center round danger 60%> | <WRAP center round danger 60%> | ||
- | | + | **DANGER**\\ Improper equipment maintenance and operation might cause personal injury or equipment damage. Before any operation, users should strictly abide by the following steps: |
- | Disconnect the AC isolation switch between the power grid and the inverter, and then turn off DC breaker of the battery box. | + | |
- | Wait for at least 10 minutes until internal energy storage elements are discharged off. During this period, don’t touch equipment terminal, contact spot, copper bar and other electric parts with body or conductor. | + | |
- | Use detecting device to check and ensure that there are no voltage and current on the device. | + | |
</ | </ | ||
- | CAUTION Stop irrelevant personnel from entering the maintenance site! | + | |
+ | |||
+ | <WRAP center round warning 60%> | ||
+ | **CAUTION**\\ Stop irrelevant personnel from entering the maintenance site!\\ | ||
During electrical connection and maintenance, | During electrical connection and maintenance, | ||
+ | </ | ||
<WRAP center round warning 60%> | <WRAP center round warning 60%> | ||
- | | + | **CAUTION**\\ The inverter can be restarted only after its malfunction affecting safety performance is removed. |
- | Power can be supplied again after the inverter is fully disconnected for 1 minute. | + | Power can be supplied again after the inverter is fully disconnected for 1 minute. |
There are no serviceable parts in the inverter. If any maintenance is required, please contact our after-sales personnel. | There are no serviceable parts in the inverter. If any maintenance is required, please contact our after-sales personnel. | ||
+ | </ | ||
<WRAP center round warning 60%> | <WRAP center round warning 60%> | ||
- | | + | **CAUTION**\\ Don’t replace the internal elements at will. Otherwise, our company will not undertake any quality guarantee and joint liability for any losses caused thereby. |
+ | </ | ||
<WRAP center round warning 60%> | <WRAP center round warning 60%> | ||
- | | + | **CAUTION**\\ Components might be damaged |
Don’t touch the circuit boards. | Don’t touch the circuit boards. | ||
+ | |||
Abide by electrostatic protection specifications and wear anti-static wrist strap. | Abide by electrostatic protection specifications and wear anti-static wrist strap. | ||
+ | </ | ||
- | ====== Others | + | |
+ | ===== Others ===== | ||
<WRAP center round warning 60%> | <WRAP center round warning 60%> | ||
- | | + | **WARNING**\\ Safety signs, warning label and nameplate on the inverter: |
- | Must be clearly visible; | + | |
- | Should not be removed or covered. | + | |
- | </ | + | </ |
| | ||
- | ====== Precautions | + | ===== Precautions ===== |
- | ===== Personnel requirements | + | ==== Personnel requirements ==== |
Energy storage inverter must be debugged and maintained by the engineers designated by the manufacturer or its agent. Otherwise, it might endanger personal safety and result in device fault. Any damage against the device caused thereby will not fall into the warranty scope. | Energy storage inverter must be debugged and maintained by the engineers designated by the manufacturer or its agent. Otherwise, it might endanger personal safety and result in device fault. Any damage against the device caused thereby will not fall into the warranty scope. | ||
- | ===== urposes | + | ==== Purposes |
Energy storage inverter is only used for commercial/ | Energy storage inverter is only used for commercial/ | ||
- | ===== Label on enclosure | + | ==== Label on enclosure ==== |
- | The label on enclosure contains important information for safe operation to the inverter. Don’t tear or damage it. | + | The label on enclosure contains important information for safe operation to the inverter. Don NOT tear down or damage it. |
The label on enclosure should be clear and readable. If it is damaged or becomes vague, please replace it. | The label on enclosure should be clear and readable. If it is damaged or becomes vague, please replace it. | ||
- | ===== Notes ===== | + | ==== Notes ==== |