manual:pws2-30k:manual_operation

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
manual:pws2-30k:manual_operation [2019/01/11 01:36]
admin [AC information]
manual:pws2-30k:manual_operation [2020/09/16 22:16] (current)
Line 10: Line 10:
     CB---CBA[AC]     CB---CBA[AC]
     CB---CBB[Battery]     CB---CBB[Battery]
-    CB---CBC[Grapgh]+    CB---CBC[Graph]
     C---CC[status]     C---CC[status]
     CC---CCA[Warnings]     CC---CCA[Warnings]
Line 57: Line 57:
    
 {{:manual:pws2-30k:image150_main_menu.jpg|}} {{:manual:pws2-30k:image150_main_menu.jpg|}}
- 
 ===== Energy ===== ===== Energy =====
  
Line 85: Line 84:
 ==== Battery information ==== ==== Battery information ====
    
-Click **Batt.** in the left side to enter, **< and **>** under the interface to turn page up or down, click {{:manual:pws2-30k:image151_return.png|}} to return the main menu. +Click **Batt.** in the left side to enter, **<** and **>** under the interface to turn page up or down, click {{:manual:pws2-30k:image151_return.png|}} to return the main menu. 
  
-^Battery information +^Battery information^Item ^Identifier ^Description ^Unit ^
-^Item ^Identifier ^Description ^Unit ^+
 |Power |P |Real-time power of battery charging and discharging |kW| |Power |P |Real-time power of battery charging and discharging |kW|
 |Voltage |U |Voltage of DC output port of inverter |V| |Voltage |U |Voltage of DC output port of inverter |V|
Line 106: Line 104:
 {{:manual:pws2-30k:image157_energy_graph.jpg|}} {{:manual:pws2-30k:image157_energy_graph.jpg|}}
 ===== Records ===== ===== Records =====
-Click **Status** in the main interface to search current warning, historical warning and logs. Click Status to enter the current warning interface. As for other interfaces in this function, click Warnings to enter. This interface includes three columns: “number”, “message” and “time”. Click **< and **>** under the interface to turn page up or down, click {{:manual:pws2-30k:image151_return.png|}} to return the main menu. +Click **Status** in the main interface to search current warning, historical warning and logs. Click Status to enter the current warning interface. As for other interfaces in this function, click Warnings to enter. This interface includes three columns: “number”, “message” and “time”. Click **<** and **>** under the interface to turn page up or down, click {{:manual:pws2-30k:image151_return.png|}} to return the main menu. 
  
 {{:manual:pws2-30k:image158_status_warning.jpg|}} {{:manual:pws2-30k:image158_status_warning.jpg|}}
  
-Click **Historical Warnings** to enter the historical warning interface. This interface includes three columns: “number”, “message” and “time end of warning”. Click **< and **>** under the interface to turn page up or down, click {{:manual:pws2-30k:image151_return.png|}} to return the main menu.+Click **Historical Warnings** to enter the historical warning interface. This interface includes three columns: “number”, “message” and “time end of warning”. Click **<** and **>** under the interface to turn page up or down, click {{:manual:pws2-30k:image151_return.png|}} to return the main menu.
    
 {{:manual:pws2-30k:image159_status_historical.jpg|}} {{:manual:pws2-30k:image159_status_historical.jpg|}}
  
 +<WRAP center round tip 60%>
 If the inverter is restarted or shut down due to power failure, the warning will still exist. After being powered on, the end time of warning will be expressed as “--/--/--”.  If the inverter is restarted or shut down due to power failure, the warning will still exist. After being powered on, the end time of warning will be expressed as “--/--/--”. 
 +</WRAP>
  
-Click **Logs** to enter the operation logs interface. This interface includes three columns: “number”, “message” and “Time before-after”. Click **< and **>** under the interface to turn page up or down, click {{:manual:pws2-30k:image151_return.png|}} to return the main menu .+Click **Logs** to enter the operation logs interface. This interface includes three columns: “number”, “message” and “Time before-after”. Click **<** and **>** under the interface to turn page up or down, click {{:manual:pws2-30k:image151_return.png|}} to return the main menu .
    
 {{:manual:pws2-30k:image160_status_log.jpg|}} {{:manual:pws2-30k:image160_status_log.jpg|}}
Line 140: Line 140:
  
  
 +<WRAP center round important 60%>
 When the dispatched apparent power exceeds 30kVA, the output of active power will be restricted by reactive power, and the system will give priority to reactive output.  When the dispatched apparent power exceeds 30kVA, the output of active power will be restricted by reactive power, and the system will give priority to reactive output. 
 +</WRAP>
  
 <WRAP center round important 60%> <WRAP center round important 60%>
Line 157: Line 159:
 ==== battery parameters ==== ==== battery parameters ====
  
-Click **Battery** to enter battery charging and discharging parameter setting. Click **< and **>** under the interface to turn page down, and click {{:manual:pws2-30k:image151_return.png|}} to return the main menu.+Click **Battery** to enter battery charging and discharging parameter setting. Click **<** and **>** under the interface to turn page down, and click {{:manual:pws2-30k:image151_return.png|}} to return the main menu.
  
 {{:manual:pws2-30k:image166_setting_battery.jpg|}} {{:manual:pws2-30k:image166_setting_battery.jpg|}}
Line 182: Line 184:
  
 ==== HMI parameters ==== ==== HMI parameters ====
-Click **HMI** to enter monitoring parameter setting. Click **< and **>** under the interface to turn page down, and click {{:manual:pws2-30k:image151_return.png|}} to return the main menu. +Click **HMI** to enter monitoring parameter setting. Click **<** and **>** under the interface to turn page down, and click {{:manual:pws2-30k:image151_return.png|}} to return the main menu. 
            
 {{:manual:pws2-30k:image169_setting_hmi_1.jpg|}} {{:manual:pws2-30k:image169_setting_hmi_1.jpg|}}
Line 215: Line 217:
 </WRAP> </WRAP>
  
 +<WRAP center round important 60%>
 When control mode is set as remote, all manual controls are disabled. When control mode is set as remote, all manual controls are disabled.
-When control mode is set as manual, all remote controls are disabled. 
  
 +When control mode is set as manual, all remote controls are disabled.
 +</WRAP>
 ==== Debug interface ==== ==== Debug interface ====
  
-Click **Debug** to enter debugging interface, and click **< and **>** under the interface to turn page down, and click {{:manual:pws2-30k:image151_return.png|}} to return the main menu.+Click **Debug** to enter debugging interface, and click **<** and **>** under the interface to turn page down, and click {{:manual:pws2-30k:image151_return.png|}} to return the main menu.
 <WRAP center round warning 60%> <WRAP center round warning 60%>
  WARNING\\ This debugging interface is used by Sinexcel electrical maintenance engineer when checking machine operation state or fault.  WARNING\\ This debugging interface is used by Sinexcel electrical maintenance engineer when checking machine operation state or fault.
Line 230: Line 233:
 Click **Hardware** to enter hardware parameter setting, and click {{:manual:pws2-30k:image151_return.png|}} to return the main menu. This interface includes output voltage grade, output frequency grade, output voltage system, and module power rating.  Click **Hardware** to enter hardware parameter setting, and click {{:manual:pws2-30k:image151_return.png|}} to return the main menu. This interface includes output voltage grade, output frequency grade, output voltage system, and module power rating. 
 <WRAP center round warning 60%> <WRAP center round warning 60%>
- WARNING Users can review hardware information in this interface, but they cannot set the parameters. Any loss arising from customers’ modifying the parameters in this interface will be undertaken by customers.+ WARNING  
 + Users can review hardware information in this interface, but they cannot set the parameters. Any loss arising from customers’ modifying the parameters in this interface will be undertaken by customers.
 </WRAP> </WRAP>
    