manual:pws2-30k:manual_operation

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
manual:pws2-30k:manual_operation [2019/01/11 01:23]
admin
manual:pws2-30k:manual_operation [2020/09/16 22:16] (current)
Line 10: Line 10:
     CB---CBA[AC]     CB---CBA[AC]
     CB---CBB[Battery]     CB---CBB[Battery]
-    CB---CBC[Grapgh]+    CB---CBC[Graph]
     C---CC[status]     C---CC[status]
     CC---CCA[Warnings]     CC---CCA[Warnings]
Line 59: Line 59:
 ===== Energy ===== ===== Energy =====
  
-Click Energy in the main interface to enter the display of energy. Users can read AC, Battery, PV, Switches and Graph information+Click **Energy** in the main interface to enter the display of energy. Users can read AC, Battery, PV, Switches and Graph information
  
 ==== AC information ==== ==== AC information ====
    
-Click Energy to enter the display of AC information (or click AC in the left side to enter), < and > under the interface to turn page up or down, click   to return the main menu. AC information is shown in the following table+Click **Energy** to enter the display of AC information (or click AC in the left side to enter), **<** and **>** under the interface to turn page up or down, click {{:manual:pws2-30k:image151_return.png|}} to return the main menu. AC information is shown in the following table
  
 ^Item ^Identifier ^Description ^Unit^ ^Item ^Identifier ^Description ^Unit^
Line 84: Line 84:
 ==== Battery information ==== ==== Battery information ====
    
-Click Batt. in the left side to enter, < and > under the interface to turn page up or down, click   to return the main menu. +Click **Batt.** in the left side to enter, **<** and **>** under the interface to turn page up or down, click {{:manual:pws2-30k:image151_return.png|}} to return the main menu. 
  
-^Battery information +^Battery information^Item ^Identifier ^Description ^Unit ^
-^Item ^Identifier ^Description ^Unit ^+
 |Power |P |Real-time power of battery charging and discharging |kW| |Power |P |Real-time power of battery charging and discharging |kW|
 |Voltage |U |Voltage of DC output port of inverter |V| |Voltage |U |Voltage of DC output port of inverter |V|
Line 101: Line 100:
 ==== Graph display ==== ==== Graph display ====
  
-Click Graph in the left side to enter the graph display. This interface can display the curve for charging and discharging power of inverter in current day. Click   to return the main menu.  +Click **Graph** in the left side to enter the graph display. This interface can display the curve for charging and discharging power of inverter in current day. click {{:manual:pws2-30k:image151_return.png|}} to return the main menu.  
    
 {{:manual:pws2-30k:image157_energy_graph.jpg|}} {{:manual:pws2-30k:image157_energy_graph.jpg|}}
 ===== Records ===== ===== Records =====
-Click Status in the main interface to search current warning, historical warning and logs. Click Status to enter the current warning interface. As for other interfaces in this function, click Warnings to enter. This interface includes three columns: “number”, “message” and “time”. Click < and > under the interface to turn page up or down, click   to return the main menu, as shown in Fig. 5 8+Click **Status** in the main interface to search current warning, historical warning and logs. Click Status to enter the current warning interface. As for other interfaces in this function, click Warnings to enter. This interface includes three columns: “number”, “message” and “time”. Click **<** and **>** under the interface to turn page up or down, click {{:manual:pws2-30k:image151_return.png|}} to return the main menu. 
  
 {{:manual:pws2-30k:image158_status_warning.jpg|}} {{:manual:pws2-30k:image158_status_warning.jpg|}}
  
-Click Historical Warnings to enter the historical warning interface. This interface includes three columns: “number”, “message” and “time end of warning”. Click < and > under the interface to turn page up or down, click   to return the main menu.+Click **Historical Warnings** to enter the historical warning interface. This interface includes three columns: “number”, “message” and “time end of warning”. Click **<** and **>** under the interface to turn page up or down, click {{:manual:pws2-30k:image151_return.png|}} to return the main menu.
    
 {{:manual:pws2-30k:image159_status_historical.jpg|}} {{:manual:pws2-30k:image159_status_historical.jpg|}}
  
 +<WRAP center round tip 60%>
 If the inverter is restarted or shut down due to power failure, the warning will still exist. After being powered on, the end time of warning will be expressed as “--/--/--”.  If the inverter is restarted or shut down due to power failure, the warning will still exist. After being powered on, the end time of warning will be expressed as “--/--/--”. 
 +</WRAP>
  
-Click Logs to enter the operation logs interface. This interface includes three columns: “number”, “message” and “Time before-after”. Click < and > under the interface to turn page up or down, click   to return the main menu .+Click **Logs** to enter the operation logs interface. This interface includes three columns: “number”, “message” and “Time before-after”. Click **<** and **>** under the interface to turn page up or down, click {{:manual:pws2-30k:image151_return.png|}} to return the main menu .
    
 {{:manual:pws2-30k:image160_status_log.jpg|}} {{:manual:pws2-30k:image160_status_log.jpg|}}
Line 121: Line 122:
 ===== Control parameter ===== ===== Control parameter =====
  
-Click Controls to enter the control interface of convert operation state. This interface includes grid-tied and off-grid control, startup and shutdown control and output power setting. Click Controls to enter “startup and shutdown” operation interface to manually start and shut down the inverter. This interface includes Clear Faults button which used to clear some fault signals which must be cleared manually. After parameter setting is completed and startup conditions are met, the inverter can be started and shut down by ON and OFF buttons. +Click **Controls** to enter the control interface of convert operation state. This interface includes grid-tied and off-grid control, startup and shutdown control and output power setting. Click **Controls** to enter “startup and shutdown” operation interface to manually start and shut down the inverter. This interface includes Clear Faults button which used to clear some fault signals which must be cleared manually. After parameter setting is completed and startup conditions are met, the inverter can be started and shut down by ON and OFF buttons. 
  
 {{:manual:pws2-30k:image161_control_start_stop.jpg|}} {{:manual:pws2-30k:image161_control_start_stop.jpg|}}
  
-Click > under the interface to turn page up to enter the inverter grid-tied and off-grid control interface. PWS2-30K-NA energy storage inverter can operate in grid-tied mode and off-grid mode. During grid-tied operation, close the isolator S2 in AC and the breaker D3 (the breaker between the inverter and the power grid.), and set the energy storage inverter in grid-tied mode through the operation interface. During off-grid operation, close the isolator S2 in AC and the AC breaker D3, turn off the AC breaker of intelligent power distribution cabinet, and set the energy storage inverter into off-grid mode.+Click **>** under the interface to turn page up to enter the inverter grid-tied and off-grid control interface. PWS2-30K-NA energy storage inverter can operate in grid-tied mode and off-grid mode. During grid-tied operation, close the isolator S2 in AC and the breaker D3 (the breaker between the inverter and the power grid.), and set the energy storage inverter in grid-tied mode through the operation interface. During off-grid operation, close the isolator S2 in AC and the AC breaker D3, turn off the AC breaker of intelligent power distribution cabinet, and set the energy storage inverter into off-grid mode.
  
 {{:manual:pws2-30k:image162_control_connectivity.jpg|}} {{:manual:pws2-30k:image162_control_connectivity.jpg|}}
  
-Click > under the interface to turn page down (or click < in “startup and shutdown” interface) to return the operation interface of “output power”. Output power can be controlled manually.  +Click **>** under the interface to turn page down (or click **<** in “startup and shutdown” interface) to return the operation interface of “output power”. Output power can be controlled manually.  
  
 Control page of electric power parameters Control page of electric power parameters
 ^Item ^Identifier ^Application scenarios ^Description^ ^Item ^Identifier ^Application scenarios ^Description^
-|Output voltage amplitude regulation |Vol. Regulation  |Off-grid mode| Regulate the output voltage amplitude in off-grid mode. Regulated range±10%|+|Output voltage amplitude regulation |Vol. Regulation  |Off-grid mode| Regulate the output voltage amplitude in off-grid mode. Regulated range ±10%|
 |Output voltage frequency regulation |Freq. Regulation |Off-grid mode|Regulate the output voltage frequency in off-grid mode. Regulated range ±1Hz| |Output voltage frequency regulation |Freq. Regulation |Off-grid mode|Regulate the output voltage frequency in off-grid mode. Regulated range ±1Hz|
 |Active power regulation |Active Power |Grid-tied mode |Regulate the active power of AC in grid-tied mode. Regulated range ±30kW| |Active power regulation |Active Power |Grid-tied mode |Regulate the active power of AC in grid-tied mode. Regulated range ±30kW|
Line 139: Line 140:
  
  
 +<WRAP center round important 60%>
 When the dispatched apparent power exceeds 30kVA, the output of active power will be restricted by reactive power, and the system will give priority to reactive output.  When the dispatched apparent power exceeds 30kVA, the output of active power will be restricted by reactive power, and the system will give priority to reactive output. 
 +</WRAP>
  
 <WRAP center round important 60%> <WRAP center round important 60%>
Line 150: Line 153:
 ===== Settings ===== ===== Settings =====
  
-Click Settings to enter the system operation parameter setting which includes Battery, HMI, Debug and Hardware parameter setting. +Click **Settings** to enter the system operation parameter setting which includes Battery, HMI, Debug and Hardware parameter setting. 
   Password is required when entering parameter setting.   Password is required when entering parameter setting.
 The initial password is 123456 The initial password is 123456
Line 156: Line 159:
 ==== battery parameters ==== ==== battery parameters ====
  
-Click Battery to enter battery charging and discharging parameter setting. Click < and > under the interface to turn page down, and click   to return the main menu.+Click **Battery** to enter battery charging and discharging parameter setting. Click **<** and **>** under the interface to turn page down, and click {{:manual:pws2-30k:image151_return.png|}} to return the main menu.
  
 {{:manual:pws2-30k:image166_setting_battery.jpg|}} {{:manual:pws2-30k:image166_setting_battery.jpg|}}
Line 181: Line 184:
  
 ==== HMI parameters ==== ==== HMI parameters ====
-Click HMI to enter monitoring parameter setting, as shown in Fig. 5 15. Click < and > under the interface to turn page down, and click   to return the main menu. The settable content of this interface is as shown in Table 5-5+Click **HMI** to enter monitoring parameter setting. Click **<** and **>** under the interface to turn page down, and click {{:manual:pws2-30k:image151_return.png|}} to return the main menu. 
            
 {{:manual:pws2-30k:image169_setting_hmi_1.jpg|}} {{:manual:pws2-30k:image169_setting_hmi_1.jpg|}}
Line 210: Line 213:
  
 <WRAP center round important 60%> <WRAP center round important 60%>
-Before clicking clear data, please consult Sinexcel service. +Before clicking **clear data**, please consult Sinexcel service. 
-After clicking restore factory settings, the inverter should be manually reboot again. Think twice before do.+After clicking *restore factory settings*, the inverter should be manually reboot again. Think twice before do.
 </WRAP> </WRAP>
  
 +<WRAP center round important 60%>
 When control mode is set as remote, all manual controls are disabled. When control mode is set as remote, all manual controls are disabled.
-When control mode is set as manual, all remote controls are disabled. 
  
 +When control mode is set as manual, all remote controls are disabled.
 +</WRAP>
 ==== Debug interface ==== ==== Debug interface ====
  
-Click Debug to enter debugging interface, and click < and > under the interface to turn page down, and click   to return the main menu.+Click **Debug** to enter debugging interface, and click **<** and **>** under the interface to turn page down, and click {{:manual:pws2-30k:image151_return.png|}} to return the main menu.
 <WRAP center round warning 60%> <WRAP center round warning 60%>
  WARNING\\ This debugging interface is used by Sinexcel electrical maintenance engineer when checking machine operation state or fault.  WARNING\\ This debugging interface is used by Sinexcel electrical maintenance engineer when checking machine operation state or fault.
Line 227: Line 231:
  
 ==== Hardware parameters ==== ==== Hardware parameters ====
-Click Hardware to enter hardware parameter setting, and click   to return the main menu. This interface includes output voltage grade, output frequency grade, output voltage system, and module power rating. +Click **Hardware** to enter hardware parameter setting, and click {{:manual:pws2-30k:image151_return.png|}} to return the main menu. This interface includes output voltage grade, output frequency grade, output voltage system, and module power rating. 
 <WRAP center round warning 60%> <WRAP center round warning 60%>
- WARNING Users can review hardware information in this interface, but they cannot set the parameters. Any loss arising from customers’ modifying the parameters in this interface will be undertaken by customers.+ WARNING  
 + Users can review hardware information in this interface, but they cannot set the parameters. Any loss arising from customers’ modifying the parameters in this interface will be undertaken by customers.
 </WRAP> </WRAP>
    
Line 235: Line 240:
 ==== Inverter information ==== ==== Inverter information ====
  
-Click About to enter the inverter information interface, as shown in Fig5 16Click   to return the main menu. This interface includes inverter serial number, MAC address, software build number, grid status and the rated power of the inverter. +Click **About** to enter the inverter information interface. click {{:manual:pws2-30k:image151_return.png|}} to return the main menu. This interface includes inverter serial number, MAC address, software build number, grid status and the rated power of the inverter. 
  
 {{:manual:pws2-30k:image175_about.jpg|}} {{:manual:pws2-30k:image175_about.jpg|}}
Line 241: Line 246:
  
  
-}}+
  • manual/pws2-30k/manual_operation.1547187795.txt.gz
  • Last modified: 2020/09/16 22:08
  • (external edit)