manual:pws2-30k:manual-operation-ex

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
manual:pws2-30k:manual-operation-ex [2020/06/23 03:23]
hedy [Detail status information view]
manual:pws2-30k:manual-operation-ex [2020/09/16 22:16] (current)
Line 75: Line 75:
 Before debugging, you need to download the Modbus software and get the communication protocol of the PCS. Usually, software and protocols should be provided by the manufacturer. Here are the steps.  Before debugging, you need to download the Modbus software and get the communication protocol of the PCS. Usually, software and protocols should be provided by the manufacturer. Here are the steps. 
  
-1. Connection+1. Connection\\ 
 1) The default communication method of the machine is Ethernet. So you need to connect with a network cable. One end of the network cable is connected to the Ethernet port of PCS, and the other end is connected to the computer. 1) The default communication method of the machine is Ethernet. So you need to connect with a network cable. One end of the network cable is connected to the Ethernet port of PCS, and the other end is connected to the computer.
 If the communication method is changed to RS485, you need to  connect the controller and inverter with shielded twisted pair. One end of the line is connected to the RS485 port of the inverter, and the other end is connected to the RS485 interface in the controller  If the communication method is changed to RS485, you need to  connect the controller and inverter with shielded twisted pair. One end of the line is connected to the RS485 port of the inverter, and the other end is connected to the RS485 interface in the controller 
Line 175: Line 175:
  
 PCS30mon PCS30mon
-^ AC parameters                    ^ Amplitude      ^ DC and diagnostic parameters       ^ Amplitude     ^ Alarms and Faults       ^  +^AC parameters                     ^Amplitude   ^ DC and diagnostic parameters   ^ Amplitude ^ Alarms and Faults  ^  
-| AC A-B RMS volatge*10            |                | DC power*100                                                             |  +| AC A-B RMS volatge*10            |            | DC power*100                                               |  
-| AC B-C RMS volatge*10            |                | DC voltage*10                                                            |  +| AC B-C RMS volatge*10            |            | DC voltage*10                                              |  
-| AC C-A RMS volatge*10            |                | DC current*10                                                            |  +| AC C-A RMS volatge*10            |            | DC current*10                                              |  
-| AC phA RMS volatge*10            |                | DC charge energy*1                                                       |  +| AC phA RMS volatge*10            |            | DC charge energy*1                                         |  
-| AC phB RMS volatge*10            |                | DC discharge energy*1                                                    |  +| AC phB RMS volatge*10            |            | DC discharge energy*1                                      |  
-| AC phC RMS volatge*10            |                | Temperature of DC heat sink*1                                            |  +| AC phC RMS volatge*10            |            | Temperature of DC heat sink*1                              |  
-| AC frequency*100                                | Address 1 content*1                                                      |  +| AC frequency*100                            | Address 1 content*1                                        |  
-| AC phA Real Power*100            |                                                                                         |  +| AC phA Real Power*100            |                                                                       |  
-| AC phB Real Power*100            |                                                                                         |  +| AC phB Real Power*100            |                                                                       |  
-| AC phC Real Power*100            |                                                                                         |  +| AC phC Real Power*100            |                                                                       |  
-| AC phA Reactive Power*100        |                                                                                         |  +| AC phA Reactive Power*100        |                                                                       |  
-| AC phB Reactive Power*100        |                                                                                         |  +| AC phB Reactive Power*100        |                                                                       |  
-| AC phC Reactive Power*100        |                                                                                         |  +| AC phC Reactive Power*100        |                                                                       |  
-| AC phA Apparent Power*100        |                                                                                         |  +| AC phA Apparent Power*100        |                                                                       |  
-| AC phB Apparent Power*100        |                                                                                         |  +| AC phB Apparent Power*100        |                                                                       |  
-| AC phC Apparent Power*100        |                                                                                         |  +| AC phC Apparent Power*100        |                                                                       |  
-| AC phA Power Factor*100          |                                                                                         |  +| AC phA Power Factor*100          |                                                                       |  
-| AC phB Power Factor*100          |                                                                                         |  +| AC phB Power Factor*100          |                                                                       |  
-| AC phC Power Factor*100          |                                                                                         |  +| AC phC Power Factor*100          |                                                                       |  
-| AC Real Power*100                |                                                                                         |  +| AC Real Power*100                |                                                                       |  
-| AC Reactive Power*100            |                                                                                         |  +| AC Reactive Power*100            |                                                                       |  
-| AC Apparent Power*100            |                                                                                         |  +| AC Apparent Power*100            |                                                                       |  
-| AC Power Factor*100              |                                                                                         |  +| AC Power Factor*100              |                                                                       |  
-| AC active discharged energy*1    |                                                                                         |  +| AC active discharged energy*1    |                                                                       |  
-| AC active charged energy*1                                                                                               |  +| AC active charged energy*1                                                                             |  
-| Reactive energy*1                |                                                                                         |  +| Reactive energy*1                |                                                                       |  
-| Temperature of AC heat sink*1    |                                                                                         |  +| Temperature of AC heat sink*1    |                                                                       |  
-| BUS+ side volatge*10                                                                                                     |  +| BUS+ side volatge*10                                                                                   |  
-| BUS- side volatge*10                                                                                                     |  +| BUS- side volatge*10                                                                                   |  
-| Target active power*10                                                                                                   |  +| Target active power*10                                                                                 |  
-| Target reactive power*10                                                                                                 |  +| Target reactive power*10                                                                               |  
-| Target off-grid volatge bias*100 |                                                                                         |  +| Target off-grid volatge bias*100 |                                                                       |  
-| Target off-grid frequency bias*10|                                                                                         +| Target off-grid frequency bias*10|                                                                       
  
  • manual/pws2-30k/manual-operation-ex.1592897032.txt.gz
  • Last modified: 2020/09/16 22:08
  • (external edit)