manual:pws2-30k:droop_mode_precautions [2022/04/05 04:46]
chloe [Scope]
manual:pws2-30k:droop_mode_precautions [2022/04/05 05:12] (current)
chloe [Side effects]
Line 10: Line 10:
 ===== Scope ===== ===== Scope =====
   * Since firmware D141, droop mode has been added to PWS2-30K/M, to provide a non-communication off-grid parallel operation solution.   * Since firmware D141, droop mode has been added to PWS2-30K/M, to provide a non-communication off-grid parallel operation solution.
-  * Only 3-phase PWS2-30K/M supports droop mode, single phase firmware can support three sets of inverter droop mode yet.+  * Single phase firmware can supports three sets of inverters droop mode yet.
 ===== To enable droop mode ===== ===== To enable droop mode =====
   * To write register 750(0x02EE) and 756(0x02F4), authorization must be granted first, by writing 2007 to register 4007(0x0FA7) and 2016 to register 4008(0x0FA8).   * To write register 750(0x02EE) and 756(0x02F4), authorization must be granted first, by writing 2007 to register 4007(0x0FA7) and 2016 to register 4008(0x0FA8).
Line 26: Line 26:
   * The droop mode will bring voltage and frequency fluctuation (90%~110%)   * The droop mode will bring voltage and frequency fluctuation (90%~110%)
   * The droop mode will bring some circulating current between each PWS2-30K/M, if the load is low in off-grid microgrid, the currents of each DC side of the PWS2-30K will be fluctuating not more than of ±5%   * The droop mode will bring some circulating current between each PWS2-30K/M, if the load is low in off-grid microgrid, the currents of each DC side of the PWS2-30K will be fluctuating not more than of ±5%
-  * **If droop mode is enabled in grid-tied mode, there will be some unpredictable reactive power, DISABLE droop mode if it's not necessary for the grid-tied operation. +
-**+