manual:pws2-30k:download_firmware_for_pws2-30k_m

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
manual:pws2-30k:download_firmware_for_pws2-30k_m [2020/01/02 01:58]
admin [2020/1/2 HMI ONLY!]
manual:pws2-30k:download_firmware_for_pws2-30k_m [2022/07/13 11:00] (current)
chloe
Line 1: Line 1:
 ====== Firmware for PWS2-30K/M ====== ====== Firmware for PWS2-30K/M ======
  
-===== 2020/1/HMI ONLY!===== +===== 2022/7/13 ===== 
-  * Version: S121 for PWS2-30K+ - A bug of a package was upgraded 
 + 
 +<WRAP center round download 60%> 
 +{{ :manual:pws2-30k:pcs30_v2022.07.13.zip |}} 
 +</WRAP> 
 + 
 +===== 2022/5/17 ===== 
 +Version:  
 +  * D147 S127(ST chip)/S503(GD chip) for PWS2-30K-NA three-phase;  
 +  * D207 S301(ST chip)/S701(GD chip) for PWS2-30K-NA Split-phase;  
 +  * D147 S213(ST chip)/S603(GD chip) for PWS2-30M-EX. 
 + - The upgrade of monitoring updates the operation logic of the EEPROM, which fix the problem that the PCS repeatedly receives the same command, causing the EEPROM to reach the erasing times in advance and demaged. 
 + 
 +<WRAP center round download 60%> 
 +{{ :manual:pws2-30k:pcs30_v2022.05.17.zip |}} 
 +</WRAP> 
 + 
 + 
 +===== 2022/3/29 ===== 
 +  * Version: D147 S126 for PWS2-30K-NA three-phase; D207 S3000 for PWS2-30K-NA Split-phase; D147 S212 for PWS2-30M-EX. 
 +  *   - Add Leakage current DC component detector enable 
 +  *   - When reach Topping charge voltage, PCS will enter standby mode 
 +  *   - Meet Tor Rule21 certification 
 +  *   - Add auto start mode 
 +  *   - Under UL1741SA certification selection, the active power can be limited by register 801 and 802 
 +  *   - AC relay detection can be closed 
 +  *   - Add fan speed register 
 + 
 +<WRAP center round download 60%> 
 +{{ :manual:pws2-30k:pcs30_147.zip | Click to download}} 
 +</WRAP> 
 + 
 + 
 +===== 2020/7/10 ===== 
 +  * Version: D144 S121 for PWS2-30K;S207 for PWS2-30M 
 +  * The off-grid frequency is now able to adjust 
 +<WRAP center round download 60%> 
 +{{ :manual:pws2-30k:pcs30_144.zip | Click to download}} 
 +</WRAP> 
 + 
 + 
 +===== 2020/3/18 HMI ONLY!===== 
 +  * Version: S1211 for PWS2-30K
   * The "beep" warning can be turned off remotely now   * The "beep" warning can be turned off remotely now
 +  * When EMS channel is selected as RS485, the EMS can still read via Ethernet
 <WRAP center round download 60%> <WRAP center round download 60%>
-{{ :manual:pws2-30k:pcs30kw_app_v121.zip |Download}}+{{ :manual:pws2-30k:pcs30kw_app_v1211.zip | Click to download}}
 </WRAP> </WRAP>
  
  • manual/pws2-30k/download_firmware_for_pws2-30k_m.1577948304.txt.gz
  • Last modified: 2020/09/16 22:07
  • (external edit)